Methodology — what this site measures, how, and what it does not claim

One page with the whole chain: the model that finds the points, the eight formulas that turn points into numbers, the weights that turn numbers into one figure, and the list of things this site refuses to state because nobody measured them.

?
There is no accuracy figure on this page, because none exists.
Nobody has scored these measurements against a ground truth — there is no ground truth for "the correct canthal tilt of this person", only a photograph and a set of points. What can be stated is repeatability, which is a different and much weaker claim, and it is stated in section 5 with the number that was actually measured.

The model

The landmark engine is MediaPipe Face Landmarker. It is served from this site's own folder rather than from a CDN, and it is fetched the first time someone presses Analyze — not when the page opens, so a reader who never runs a photo never pays the download.

The photo is read inside the tab. The page's Content-Security-Policy carries connect-src 'self', so the browser itself refuses a connection to any other origin — the "nothing is uploaded" claim is enforced by the browser rather than promised by the page.

The eight measurements

Each row is computed from landmark indices on the 478-point mesh, compared against a reference value and a band around it. The same table is printed on the test page next to your own values; this is the version without a photo.

MeasurementLandmarksHow it is computedReferenceBand
Bilateral symmetry 12 mirrored pairs, midline 168→152 Signed perpendicular distance of each mirrored pair to the midline; the pair error is the two distances added, since a perfect mirror cancels them. Averaged over 12 pairs, divided by face width (234→454). 0 (perfect mirror) 2.0% of face width
Facial thirds 10, 9, 2, 152 Mesh top → brow line, brow line → subnasale, subnasale → chin. Average deviation of the three heights from an even split, as a share of one third. 0 (even thirds) 35% of one third
Facial fifths 234, 33, 133, 362, 263, 454 Five horizontal segments across the face at eye level. Average deviation of the five from an even split, as a share of one fifth. 0 (even fifths) 25% of one fifth
Face length to width 10, 152, 234, 454 Mesh top → chin, divided by cheek edge → cheek edge. 1.618 (phi) ±0.45 around phi
Canthal tilt 133→33, 362→263 Angle of the inner-to-outer eye corner line, per eye; positive means the outer corner sits higher. Reported as the average of the two eyes. 0° (level) ±6°
Midface ratio 468, 473, 2 Interpupillary distance divided by the vertical distance from the pupil line to the subnasale. 1.4 ±0.25
Jaw width ratio 172, 397, 234, 454 Jaw width at the two jaw corners, divided by face width. 0.76 ±0.10
Mouth to nose width 61, 291, 98, 327 Mouth width divided by nose width at the alae. 1.6 ±0.25

Weights, and the band scale

Two different controls sit in section 4 of the test page, and they do different things. The band scale widens or tightens all eight reference bands at once; it moves how many measurements count as inside their band, and it moves the 0–100 geometry reference match. The per-measurement sliders only decide how much each band contributes to that one figure — they never move a single measured value.

MeasurementDefault weight
Bilateral symmetry25
Facial thirds15
Facial fifths15
Face length to width15
Canthal tilt10
Midface ratio10
Jaw width ratio5
Mouth to nose width5

The weights are this site's own choice, not a published scheme. They are printed in the interface and adjustable there for exactly that reason: a weighted average hides its weights unless someone puts them on the screen.

Advertising, and what it can see

The ad loader is on every page except the result page and the 404 page, including the pages that open a photo. So on the tool pages, Google's ad script runs in the same document as the measurement. That is a weaker arrangement than a site with no third-party script at all, and it is stated here rather than glossed over.

What is true without qualification: no request this site makes carries the photo, and there is no endpoint here that would accept one. A script in the same document could in principle read what a file input holds, which is why the promise on this site is "our code never passes the image anywhere" and not "no script could reach it". The ad code has no documented reason to touch a file input, and nothing in this site's code hands it one — but that is a statement about code, not a sandbox.

What the page does control is where it can connect. The Content-Security-Policy in the response header names every origin: this one, the page counter, and the Google ad hosts. A host outside that list is refused by the browser. That is checkable in two places — read the header, or open the network panel and watch which hosts are contacted while a photo is measured. The privacy page carries the item-by-item data table.

What this site does not claim

Photos, repeatability and accuracy

Most of the variation between two runs on the same face comes from the photo, not from the model: a few degrees of head turn, a different focal length, a light source on one side, or a different expression all move the landmarks enough to move the numbers. A front-facing photo with even light and a neutral expression is the setup the reference bands assume, and it is the only setup in which the numbers are comparable to each other.

Repeatability was measured and is stated as a number: the same photo returns identical values on repeat runs, and the two compute paths place the same landmark about 4 px apart on average on a 1024 px detect image — which moved the composite by one point on the test photo. That is repeatability. It is not accuracy, and the difference matters: a ruler that is consistently wrong is perfectly repeatable.

Browsers actually tested

Only what was driven end to end is listed here. Anything not on this list has not been tested, which is a different statement from "does not work".

BrowserPlatformResult
Chrome 154Windows, desktopFull flow: photo in, 478 landmarks, eight measurements, CSV / JSON / PNG out
Chrome 157.0.8103.80Windows, desktopRe-run on 2026-11-20: same flow, same result — 478 landmarks, eight measurements, CSV / JSON out. Edge was not re-run that day.
Edge 154Windows, desktopSame flow, same result
Firefox 155Windows, desktopFails: the landmark engine aborts inside its WebAssembly module, on both compute paths
Firefox 160Windows, desktopFails in the same place — re-checked on Firefox 160.0 on 2026-11-20: the engine builds, then the first detection aborts (wasm trap), on the GPU path, the CPU path and the no-SIMD build alike. No 17 MB download is spent there any more; the page says so up front.
Phones, tablets, Safari—Not tested by this site. No claim is made either way.

This table is updated only when a run is actually performed, and the version numbers are the ones printed by the browser during that run. Copying a version number from memory is how a browser matrix becomes fiction.

Methodology questions

What model does this site use?

MediaPipe Face Landmarker, shipped with the page rather than loaded from a CDN. It returns 478 points: 468 on the face surface and 10 on the irises, five per eye. The model file is about 3.6 MB and the WebAssembly runtime around 13 MB; both are fetched the first time someone presses Analyze, then cached by the browser.

How accurate is the measurement?

No accuracy figure is claimed, because none has been measured against a ground truth. What is stated instead is repeatability: the same photo returns identical values on repeat runs, and the two compute paths place the same landmark about 4 px apart on average on a 1024 px detect image. Repeatability is not accuracy — it says the arithmetic is stable, not that the arithmetic is right.

Where do the reference bands come from?

From classical proportion canons — the even thirds and fifths of traditional portraiture, phi at 1.618, and the ranges quoted in the cosmetic and orthodontic literature for the ratios that have them. They are not a validated standard of attractiveness, and the width of each band is this site's own choice, adjustable on the page so the effect of that choice is visible.

Which browsers were actually tested?

The tool page was driven end to end in Chrome 157 and Edge 154 on Windows: photo in, 478 landmarks, eight measurements, all exports out. Firefox 155 and 160 were tested the same way and the landmark engine aborts inside its WebAssembly module there, on both compute paths, so the page reports that instead of a number. That was re-checked on Firefox 160.0 on Windows on 2026-11-20, and the engine now never starts there — the page says so before a byte of the model is downloaded. No other browser has been tested, and no phone has been tested by the people who build this site.

Where to go next